PSS particle analysis: choose the measurement before the model.
AccuSizer SPOS particle counting and Nicomp DLS particle sizing serve different questions. Zhongfu Semiconductor helps organize official documentation, configuration inputs and project enquiries.
Sources checked: November 2, 2026 · Zhongfu Optoelectronic Technology (Wuhan) Co., Ltd.
What is Entegris PSS?
PSS here means Particle Sizing Systems, LLC. Entegris announced its acquisition on January 22, 2018. The current Entegris AccuSizer SPOS and Nicomp DLS product pages identify the two particle-analysis routes covered here.[1–3] A series name is a starting point; the exact instrument, sampling system, sensor, software and supplied accessories must be identified in the quotation.


AccuSizer SPOS and Nicomp DLS answer different questions.
| Route | Published function | Application inputs | Boundary |
|---|---|---|---|
| AccuSizer / SPOS | Single-particle optical sensing for individual-particle size and number concentration.[2] | Large-particle tail or LPC target, sample concentration, sampling location, measurement volume and dilution method. | A count measured after dilution requires the documented dilution and reporting basis before comparison with original-fluid acceptance limits. |
| Nicomp / DLS | Dynamic light scattering for nanoscale particle-size analysis; zeta potential is configuration-dependent.[3] | Dispersion, concentration, medium properties and the intended particle-size or electrokinetic measurement. | DLS particle-size results do not replace individual-particle SPOS counts or an LPC acceptance criterion. |
Separate the model from the sampling configuration.
| Family | Official positioning | Confirm for the project |
|---|---|---|
| AccuSizer Mini FLEX | Online large-particle counting in CMP slurry; bottle-sample operation is also available.[4] | Sampling point, bypass, dilution water, flushing, LPC thresholds, alarms and data interfaces. Online positioning does not establish fit with every production system. |
| AccuSizer A7000 DI | Automated batch analysis for alumina and similar slurries, with autosampling and dilution.[5] | Batch size, mixing, sample volume, operating/dilution mode, blanks and carryover verification. |
| AccuSizer A7000 SIS | Syringe-injection system; the current datasheet addresses USP <788>. It is a different sampling route from the DI batch system.[6] | Syringe and wetted flow path, injection volume, concentration, operating method and cleaning. Do not transfer DI configuration or throughput assumptions; semiconductor sample methods require separate verification. |
| Nicomp N3000 / Z3000 | N3000 particle-size analysis; Z3000 adds zeta-potential analysis.[3] | Required measurements, cells/electrodes, medium conditions, software licences and reporting. Z3000 functionality is not automatically included in N3000. |
Make sampling, dilution and cleaning part of acceptance.
For an online installation, document sampling representativeness, transport delay, bypass arrangements and switching/cleaning. For bottle samples, preserve sample identification, mixing, dilution, blanks and repeat-test settings. Settling, bubbles, concentration effects and carryover can affect comparability even when the optical measurement runs successfully.
The A7000 DI datasheet describes operating modes, mixing, individual pipette tips and washing.[5] These features identify validation work; they do not establish zero carryover for every sample. Range, flow, pressure, wetted materials, calibration, sample compatibility and acceptance criteria need the exact configuration and current controlled documents.
Build a comparable PSS procurement request.
A useful RFQ includes the complete model or nameplate, sample medium/SDS, concentration and permitted composition information, size or LPC target, sample volume, online/bottle/syringe route and expected workload. Add the installation location, utilities, communications, data retention, software version/licensing, calibration documents, IQ/OQ, training and maintenance scope. Identify which party will provide each service before comparing quotations.
Buyers searching for a PSS agent, distributor or Entegris PSS source should verify the legal supply entity, territory, product-series scope and validity of the supporting documents. Content/image-use permission does not establish sales authorization. Zhongfu coordinates documentation and project enquiries; manufacturer, source, applicable authorization, supplied configuration, service provider, origin, documents, price and lead time are confirmed in the written quotation.
Frequently asked questions
What does PSS mean here?
Can AccuSizer and Nicomp results be substituted?
How should a buyer verify a PSS agent or distributor?
What does Zhongfu need for a PSS enquiry?
Official references
- Entegris acquisition of Particle Sizing Systems, LLC — January 22, 2018
- Entegris AccuSizer SPOS Systems — System Features / Applications
- Entegris Nicomp Nano DLS/ZLS Systems — System Features
- AccuSizer Mini FLEX Data Sheet — 7127-12974ENT-0623, pp.1–4
- AccuSizer A7000 DI Data Sheet — 7127-10462ENT-0626, pp.1–3
- AccuSizer A7000 SIS Data Sheet — 7127-10463ENT-0326, pp.1–2
Published information is used for initial screening. Final configuration, sample compatibility and acceptance require current manufacturer documentation, sample verification and written confirmation. No stock, delivery, performance-equivalence or official-service commitment is inferred from a series overview.