Semiconductor liquid and gas filtrationInternational enquiries: [email protected] · +86 155 2706 2747
Entegris PSS · AccuSizer · Nicomp

PSS particle analysis: choose the measurement before the model.

AccuSizer SPOS particle counting and Nicomp DLS particle sizing serve different questions. Zhongfu Semiconductor helps organize official documentation, configuration inputs and project enquiries.

Sources checked: November 2, 2026 · Zhongfu Optoelectronic Technology (Wuhan) Co., Ltd.

What is Entegris PSS?

PSS here means Particle Sizing Systems, LLC. Entegris announced its acquisition on January 22, 2018. The current Entegris AccuSizer SPOS and Nicomp DLS product pages identify the two particle-analysis routes covered here.[1–3] A series name is a starting point; the exact instrument, sampling system, sensor, software and supplied accessories must be identified in the quotation.

Official Entegris AccuSizer SPOS series equipment image
AccuSizer SPOS series image from Entegris.[2] It identifies the product route and does not establish an exact supplied configuration.
Official Entegris Nicomp DLS series equipment image
Nicomp N3000 image from Entegris.[3] It illustrates DLS particle-size analysis. Zeta-potential capability requires a separately confirmed configuration such as Z3000.

AccuSizer SPOS and Nicomp DLS answer different questions.

RoutePublished functionApplication inputsBoundary
AccuSizer / SPOSSingle-particle optical sensing for individual-particle size and number concentration.[2]Large-particle tail or LPC target, sample concentration, sampling location, measurement volume and dilution method.A count measured after dilution requires the documented dilution and reporting basis before comparison with original-fluid acceptance limits.
Nicomp / DLSDynamic light scattering for nanoscale particle-size analysis; zeta potential is configuration-dependent.[3]Dispersion, concentration, medium properties and the intended particle-size or electrokinetic measurement.DLS particle-size results do not replace individual-particle SPOS counts or an LPC acceptance criterion.

Separate the model from the sampling configuration.

FamilyOfficial positioningConfirm for the project
AccuSizer Mini FLEXOnline large-particle counting in CMP slurry; bottle-sample operation is also available.[4]Sampling point, bypass, dilution water, flushing, LPC thresholds, alarms and data interfaces. Online positioning does not establish fit with every production system.
AccuSizer A7000 DIAutomated batch analysis for alumina and similar slurries, with autosampling and dilution.[5]Batch size, mixing, sample volume, operating/dilution mode, blanks and carryover verification.
AccuSizer A7000 SISSyringe-injection system; the current datasheet addresses USP <788>. It is a different sampling route from the DI batch system.[6]Syringe and wetted flow path, injection volume, concentration, operating method and cleaning. Do not transfer DI configuration or throughput assumptions; semiconductor sample methods require separate verification.
Nicomp N3000 / Z3000N3000 particle-size analysis; Z3000 adds zeta-potential analysis.[3]Required measurements, cells/electrodes, medium conditions, software licences and reporting. Z3000 functionality is not automatically included in N3000.

Make sampling, dilution and cleaning part of acceptance.

For an online installation, document sampling representativeness, transport delay, bypass arrangements and switching/cleaning. For bottle samples, preserve sample identification, mixing, dilution, blanks and repeat-test settings. Settling, bubbles, concentration effects and carryover can affect comparability even when the optical measurement runs successfully.

The A7000 DI datasheet describes operating modes, mixing, individual pipette tips and washing.[5] These features identify validation work; they do not establish zero carryover for every sample. Range, flow, pressure, wetted materials, calibration, sample compatibility and acceptance criteria need the exact configuration and current controlled documents.

Build a comparable PSS procurement request.

A useful RFQ includes the complete model or nameplate, sample medium/SDS, concentration and permitted composition information, size or LPC target, sample volume, online/bottle/syringe route and expected workload. Add the installation location, utilities, communications, data retention, software version/licensing, calibration documents, IQ/OQ, training and maintenance scope. Identify which party will provide each service before comparing quotations.

Buyers searching for a PSS agent, distributor or Entegris PSS source should verify the legal supply entity, territory, product-series scope and validity of the supporting documents. Content/image-use permission does not establish sales authorization. Zhongfu coordinates documentation and project enquiries; manufacturer, source, applicable authorization, supplied configuration, service provider, origin, documents, price and lead time are confirmed in the written quotation.

Frequently asked questions

What does PSS mean here?
PSS refers to Particle Sizing Systems, LLC. Entegris announced the acquisition on January 22, 2018. The current official AccuSizer SPOS and Nicomp DLS product pages establish the product identity discussed here.
Can AccuSizer and Nicomp results be substituted?
No. AccuSizer SPOS measures individual-particle size and number concentration, while Nicomp uses dynamic light scattering for nanoscale particle-size analysis. Zeta potential depends on the selected configuration. Define the measurand and acceptance method first.
How should a buyer verify a PSS agent or distributor?
Verify the legal quotation entity, supply route, territory, product series and validity period against current written evidence. Website content or permission to reproduce manufacturer images does not itself establish sales or service authorization.
What does Zhongfu need for a PSS enquiry?
Send the complete model or nameplate, sample medium or SDS, concentration, measurement target, sampling mode, installation location and software/documentation requirements. Supply identity, configuration, documents, service scope, price and lead time are confirmed in writing per project.

Official references

  1. Entegris acquisition of Particle Sizing Systems, LLC — January 22, 2018
  2. Entegris AccuSizer SPOS Systems — System Features / Applications
  3. Entegris Nicomp Nano DLS/ZLS Systems — System Features
  4. AccuSizer Mini FLEX Data Sheet — 7127-12974ENT-0623, pp.1–4
  5. AccuSizer A7000 DI Data Sheet — 7127-10462ENT-0626, pp.1–3
  6. AccuSizer A7000 SIS Data Sheet — 7127-10463ENT-0326, pp.1–2

Published information is used for initial screening. Final configuration, sample compatibility and acceptance require current manufacturer documentation, sample verification and written confirmation. No stock, delivery, performance-equivalence or official-service commitment is inferred from a series overview.

Send the model and the measurement problem.

Zhongfu Optoelectronic Technology (Wuhan) Co., Ltd. · Zhongfu Semiconductor / 众甫光电科技(武汉)有限公司

Phone/WeChat: +86 155 2706 2747
Email: [email protected]

Request a project quotation 中文 PSS 资料 →